- Provides 90000VA, 90kW, 90000watt(s) power
- Surge Suppression is Standard
- 4.20 minute(s) Battery Runtime at Full Load
Tripp Lite's SVX90KM3P5B 90kVA/90kW SmartOnline Medium-Frame UPS includes installed input, bypass and output breakers, a static transfer switch (STS) and 3 included 30kVA SVX30PM power modules. This system supports the addition of 1 additional user-installable SVX30PM power module to accommodate 90kW total capacity with N+1 fault-tolerance. Five internal battery modules are included to fully load internal battery compartments. Additional runtime is available using any number of compatible ±240VDC external battery packs (sold separately).
Featuring a modular, scalable design with high-efficiency voltage and frequency independent/VFI operation, Tripp Lite's SVX Series SmartOnline UPS systems are ideal for the protection of a wide variety of critical IT systems. Scalable, modular configuration enables UPS capacity upgrades and hot-swap power supply maintenance without costly downtime. Over 95% efficient in standard online mode and over 99% efficient in optional economy mode enables reduced operating and cooling costs. Unity power factor configuration provides equal kVA and kW output ratings for up to 25% more wattage capacity than common 0.8 – 0.9 power factor competing designs. Network-grade sine-wave AC output with 1% output voltage regulation and less than 1.5% output total harmonic distortion. Advanced IGBT inverter with Digital Signal Processor (DSP) technology provides for less than 3% input total harmonic distortion (THDi) to support 1:1 generator sizing. Dual-input hardwire design enables operation from one or two input power sources for enhanced system availability. N+1 fault-tolerance is configurable anytime there is an "extra" SVX30PM 30kW power module installed beyond the minimum required quantity. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure
Featuring a modular, scalable design with high-efficiency voltage and frequency independent/VFI operation, Tripp Lite's SVX Series SmartOnline UPS systems are ideal for the protection of a wide variety of critical IT systems. Scalable, modular configuration enables UPS capacity upgrades and hot-swap power supply maintenance without costly downtime. Over 95% efficient in standard online mode and over 99% efficient in optional economy mode enables reduced operating and cooling costs. Unity power factor configuration provides equal kVA and kW output ratings for up to 25% more wattage capacity than common 0.8 – 0.9 power factor competing designs. Network-grade sine-wave AC output with 1% output voltage regulation and less than 1.5% output total harmonic distortion. Advanced IGBT inverter with Digital Signal Processor (DSP) technology provides for less than 3% input total harmonic distortion (THDi) to support 1:1 generator sizing. Dual-input hardwire design enables operation from one or two input power sources for enhanced system availability. N+1 fault-tolerance is configurable anytime there is an "extra" SVX30PM 30kW power module installed beyond the minimum required quantity. Automatic and manual bypass options keep connected equipment operational during routine maintenance or critical power module failure
-
1979.00 lb(s)
-
Features:
Offers network-grade power protection in a highly configurable medium-frame modular, scalable form factor
Includes 3 SVX30PM 30kW power modules for 90kVA total capacity; Open slots for 1 additional SVX30PM 30kW power module enable enhanced N+1 redundancy
Included batteries support a full load of 90kW for 4.2 minutes and half load of 45kW for 8.8 minutes; Extended runtime is available with the addition of any number of supported external battery packs (sold separately)
Supports 220/380, 230/400 or 240/415V AC, 3-Phase Wye 4-Wire plus Earth Hardwire input and output wiring
Tested to CE for worldwide applications
Pre-installed WEBCARDLX network interface
Serial port enables unattended shutdown and UPS monitoring ability
Modular configuration with hot-swappable power modules enables easy and fast maintenance with zero downtime
Wide input voltage operating range enables full continuous online operation during brownouts as low as 120V (Ph-N) and overvoltages up to 276 (Ph-N)
Narrow output voltage operating range regulates output voltage within 1% of the selected 220/230/240 nominal output voltage in online, double-conversion mode
Over 95% efficient in online, double-conversion mode and over 99% efficient in optional economy-mode enables reduced operating and cooling costs
Less than 3% input Total Harmonic Distortion (THDi) prevents the need to oversize generator systems relative to UPS capacity
Dual hardwire input design enables operation from one or two input power sources
Front panel combination LCD/LED display offers full UPS condition and status reporting plus additional configuration options -
Communication Interface: Serial (RS-232)
-
UPS system, (3) SVX30PM 30kVA power modules, (5) SVXBM battery modules, pre-installed WEBCARDLX network interface, documentation
-
Color: BlackForm Factor: Tower
-
79.13"H x 23.62"W x 43.3"D
-
Battery Run Time (max): 4.20 minute(s)Power Provided: 90 kW, 90000 VA, 90000 watt(s)Surge Suppression: Standard
-
Output Volt Amp Capacity (VA): 90000
Output kVA Capacity (kVA): 90
Output Watt Capacity (Watts): 90000
Output kW Capacity (kW): 90
Output Capacity Details: OVERLOAD CAPABILITY: Supports 105-110% load for 1 hour, 111-125% load for 10 minutes, 126-150% for 1 minute and Over 150% for 200ms before switching to Bypass; Online operation resumes when load is reduced to 100% or less
Power Factor: 1.0
Crest Factor: 3:1
Nominal Output Voltage(s) Supported: 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
Nominal Voltage Details: Output THD full resistive load: <1.5%; Output THD non-linear load: <4%; Max DC offset: ±50mV; Max Phase angle deviation: 2°; Max Voltage unbalance deviation: 1%; Output short-circuit protection included
Frequency Compatibility: 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details: Auto-selectable, user adjustable
Output Receptacles: Hardwire
Output Receptacle Details: Output wiring (3P, N, E)
Output Circuit Breakers: 400A 3 pole magnetic breaker
Output AC Waveform (AC Mode): Pure Sine wave
Output AC Waveform (Battery Mode): Pure Sine wave
Output Voltage Regulation: ONLINE, FREQUENCY CONVERSION, BATTERY MODE: 220/230/240V ±1% typical (balanced load); ±2% typical (unbalanced load); ECONOMY MODE: 220/230/240V ±15V; BYPASS MODE: +15% (default, adjustable to +10%, +15% or +20%), -20% (default, adjustable to -10%, -20%, -30%)
Output Frequency Regulation: ONLINE MODE: Output frequency is ±0.05Hz of input frequency when input is within ±4Hz* of the configured 50/60Hz output setting; Output frequency is ±0.05Hz the configured 50/60Hz output setting when input is outside ±4Hz* of the configured 50/60Hz output setting; BATTERY MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; FREQUENCY CONVERTER MODE: Output frequency is ±0.1Hz of the configured 50/60Hz output setting; ECONOMY MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (UPS switches to Online mode if frequency goes outside of this range); BYPASS MODE: Output frequency equals input frequency up to ±4Hz* of the configured 50/60Hz output setting (switches to STANDBY mode if frequency goes outside of this range). *The TRACKING RANGE is factory set to ±4Hz and is user adjustable to ±1Hz, ±2Hz or ±4Hz; The selected TRACKING RANGE setting controls frequency output tolerances as described above in Online, Economy and Bypass modes
Output Amp Capacity: 137A (220/380V); 130A (230/400V); 125A (240/415V)
Modular Upgrade Options: Includes 3 SVX30PM 30kVA power modules; 1 additional SVX30PM 30kVA power module can be added for N+1 availability; Add 1 SVX30PM for 90kVA capacity with N+1 redundancy
Rated input current (Maximum Load): 110A Maximum
Nominal Input Voltage(s) Supported: 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
Nominal Input Voltage Description: Set of two hardwire input connections enables 3-Phase Wye, 4 wire (3P, N, E) inputs from two separate power sources
UPS Input Connection Type: Hardwire
Input Circuit Breakers: MAIN and ALTERNATE AC inputs are each protected by 400A 3 pole magnetic breakers
Input Phase: 3-Phase
Input Frequency: 40 to 70Hz (online mode); 50/60Hz Auto-selectable
Power Factor (Input): Greater than 0.99 (full load)
THDi: Less than 3% (full linear load)
Full Load Runtime (min.): 4.2 minutes (90kW)
Half Load Runtime (min.): 8.8 minutes (45kW)
Expandable Battery Runtime: Supports extended runtime with optional external battery packs; 100A 3 pole 250VDC breaker recommended for external battery
External Battery Pack Compatibility: BP480V200; BP480V300; BP480V400; BP480V500; BP480V370
Expandable Runtime Description: External battery pack wiring is contractor supplied; All external battery configurations require the disconnection of internal battery modules
DC System Voltage (VDC): +/- 240VDC
Battery Recharge Rate (Included Batteries): User selectable charging current of 1A to 8A (2A factory setting); Recharge rate is dependent on number of external battery packs connected and the selected charge current setting
Battery Replacement Description: Hot-swappable, replaceable batteries
Expandable Runtime: Yes
Voltage Regulation Description: Online, double-conversion power conditioning
Overvoltage Correction: Maintains continuous output in online mode, without using battery power, during overvoltages to 478V (Ph-Ph), reducing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage
Undervoltage Correction: Maintains continuous output in online mode, without using battery power, during brownout/undervoltage conditions to 305V (Ph-Ph) at full load and to 208V (Ph-Ph) at 70% output load or less, increasing output to within 1% of selected 380/220V, 400/230V, 415/240V nominal output voltage
Front Panel LCD Display: 145mm front panel LCD display with directional scroll and select buttons offers complete operating status display, plus setting and selection options for all UPS functions
Switches: Front panel buttons include ESC (menu escape), UP/LEFT (menu up / left), DOWN/RIGHT (menu down / right), ENTER (confirm selection), HOME (return to home screen) and POWER (on/off power control); Also includes Manual Bypass switch
Alarm Cancel Operation: Audible alarms can be muted using on-screen prompts
Audible Alarm: Unique audible alarms for POWER ON / POWER OFF (alarm sounds for 2 seconds), BATTERY MODE (alarm sounds every 2 seconds), LOW BATTERY (alarm sounds every 0.5 seconds), UPS ALARM (alarm sounds every 1 second), UPS FAULT (continuous alarm)
LED Indicators: Front panel LED indicators represent INPUT (green), BYPASS (amber), INVERTER (green), BATTERY (red) and ALARM (red)
EMI / RFI AC Noise Suppression: Yes
AC Suppression Joule Rating: 2496
AC Suppression Joule Rating Details: 2496 joules (Ph-Ph), 2496 joules (Ph-N), 1872 joules (N-E)
AC Suppression Response Time: Instantaneous
Installation Form Factors Supported with Included Accessories: Tower
Primary Form Factor: Tower
Cooling Method: Fans
UPS Housing Material: Steel
Operating Temperature Range: 0 to +40C (+32 to +104F); De-rates to 90% capacity at 35C / 95F and 80% capacity at 40C / 104F
Storage Temperature Range: -15 to +60C (+5 to +140F)
Relative Humidity: 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load): 17200
AC Economy Mode BTU / Hr. (Full Load): 3100
AC Mode Efficiency Rating (100% Load): 95%
AC Economy Mode Efficiency Rating (100% Load): 99%
Audible Noise: Less than 73 DBA front-side, 1m
Operating Elevation (m): Up to 1000m (At elevations over 1000m, output de-rates by 1% per 100m)
Communications Interface: DB9 Serial; EPO (emergency power off); Pre-installed network card; Slot for SNMP/Web interface
Network Management Cards: WEBCARDLX
Network Monitoring Port Description: Includes pre-installed Tripp Lite WEBCARDLX network interface
PowerAlert Software: For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable: DB9 cabling included
SNMP Compatibility: Includes pre-installed WEBCARDLX network interface card
Transfer Time: No transfer time (0 ms.) in online, double-conversion mode; Less than 20 ms. transfer time in economy mode
Low Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation without using battery power during brownout/undervoltage conditions to 305V (Ph-Ph) Full load or 208V (Ph-Ph) 70% load or less; Below the low transfer voltage point, output is maintained utilizing reserve battery power
High Voltage Transfer to Battery Power (Setpoint): Maintains continuous operation without using battery power during overvoltages to 478V (Ph-Ph), reducing output within 1% of nominal; Above this point, output is maintained utilizing reserve battery power
Cold Start (Startup in Battery Mode During a Power Failure): Cold-start operation supported
High Availability UPS Features: Automatic inverter bypass; Hot swappable batteries
Green Energy-Saving Features: Greater than 95% efficiency - GREEN UPS; High efficiency economy mode operation; Schedulable daily hours of economy mode operation -
This product is subject to our return policy. Please see our complete return policy for details.
-
Compliant Standards: CE, EN 62040-2:2006, IEC 62040-1:2008, RoHS
-