            Ordering Information

            Tripp Lite 3 phase Monitored PDU / Power Distribution Unit offers real-time remote monitoring of voltage, frequency and load levels via built-in network connection. PowerAlert interface supports custom notification of user-specified remote conditions via email, secure web, SNMP, Telnet or SSH interface. PDU output current consumption in amps is displayed per-phase via front panel lighted digital display and can be monitored remotely to warn of potential overloads before critical IT mains breakers trip.
            Collapse & Return to Top
            Actual Weight 13.50 lb(s)
            Compatibility Notes Key Features

            5.8kW 3-phase 208V Monitored Power Distribution Unit/PDU with built-in web/network interface
            Attached NEMA L21-20P 3-phase input plug with 6ft/1.8m cord
            0U, 70"/178cm vertical form factor supports installation in 2 or 4-post equipment racks
            (36) C13 (208V), (6) C19 (208V) and (3) NEMA 5-15/20R outlets arranged in 3 single phase output load banks
            Network interface provides PDU data regarding input voltage and per-phase load levels with +/-1% billing-grade accuracy
            Built-in local digital display and remote web/network interface reports detailed voltage, amperage and kilowatt output values per phase with additional reporting options for power unbalance percentage, IP address and sensor* based temperature and humidity data (*requires ENVIROSENSE sensor)
            In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack access notification with up to 4 optional SRSWITCH door sensors
            Local display supports electronic 180 degree display rotation for overhead or under-floor input cable orientation
            Supports user-specified alarm notification thresholds
            DHCP/Manual configuration support
            10/100 Mbps auto-sensing
            Real-time clock backup maintains the time of day and date even if the PDU is unpowered
            Tiered access privileges allow an administrator and a guest to login via web browser
            Alert notifications via email or SNMP traps offer immediate event notification
            Firmware upgrade ability supports future product enhancements
            Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
            Fully compatible with FREE PowerAlert Network Management System / NMS Software
            Included set of Plug-lock inserts keep C14 power cords solidly connected to PDU outlets
            Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons included)
            Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases


            Front Panel LCD Display - Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature* and Humidity* information (*requires ENIVIROSENSE option, available separately); Small digital display provides detail on the measurement the large display is reporting -- Input-phase (L#), Load bank (B#), Sensor (S#), Load unbalance (UB), Output power (OP)
            Reported Load Segments - Supports monitoring of input current per phase (L1,L2,L3) and output current for each output load bank (B1-B6); Outlets are color-coded and labelled for phase and load bank identification; L1-L2 feeds black C13/C19 outlets (B1); L2-L3 feeds dark-gray C13/C19 outlets (B2); L3-L1 feeds light-gray C13/C19 outlets (B3); L1-N feeds black 5-20R outlet (B4); L2-N feeds dark-gray 5-20R outlet (B5); L3-N feeds light-gray 5-20R outlet (B6)
            Front Panel LEDs - Set of (6) LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V), Unbalance percentage (%UB), Temperature (T), Humidity (%RH); 3 additional multi-color LEDs offer power availability information for each pair of output load banks (Bank 1&4 / Bank 2&5 / Bank 3&6): GREEN (<80% load), YELLOW (>80% load), RED (Power OFF), RED FLASHING (Power OFF/breaker trip)
            Switches - Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options; Additional MODE button advances the LEDs to view the next measurement


            Material of Construction - Steel
            Form Factors Supported - Vertical rackmount installation supported with included mounting brackets; supports tooless mounting in button-mount compatible racks
            PDU Form Factor - Vertical (0U)


            Tested to UL60950-1 (USA) CAN60950-1 (Canada), NOM (Mexico), Class A (Emissions), RoHS, TAA Compliant
            # Ports 45
            Connector Power IEC 320 EN 60320 C13, Power IEC 320 EN 60320 C19, Power NEMA 5-20 (F), Power NEMA L21-30 (M)
            Contents PDU, pre-installed mounting buttons, spare installation buttons (2) 9mm/(4) 6mm, cable retention sleeves, rack mounting brackets, documentation
            Color Black
            Form Factor 0U Rackmount
            Physical Dimensions 70"h x 2.2"w x 2.5"d
            Ports/Connectors Outlet Quantity / Type: (3) 5-15/20R; (36) C13; (6) C19
            Number of Outlets: (45)
            PDU Plug Type: NEMA L21-20P
            Input Cord Length: 6ft/1.8m
            Power Provided 208 V
            Power Notes OUTPUT

            Output Capacity Details - 5.8kW total capacity; 9.2A (208V) / 16A (120V) max per output phase; 16A max per 5-20R outlet
            Frequency Compatibility - 50/60Hz
            Output Nominal Voltage - 208 & 120V single phase


            PDU Input Voltages - 208V
            Maximum Input - 16A
            Phase - 3-Phase
            Returns Policy This product is subject to our return policy. Please see our complete return policy for details.
            Compliant Standards CAN/CSA C22.2 No. 60950-1, FCC Class A certified, NOM, RoHS, TAA, UL 60950-1
            UNSPSC 39121017
            Warranty - Labor 2 Years
            Warranty - Parts 2 Years
            Collapse & Return to Top
            Add this product to your cart with selected accessories
            Add To Cart
            Environmental Monitoring (1 Product)
            Power Cords (8 Products)
            Add this product to your cart with selected accessories
            Add To Cart
            Collapse & Return to Top

            Our Accessibility Policy

            We endeavor to make our website accessible to any and all users. Please contact us toll-free at 800-998-4388 if you need assistance with navigating our blog, website, or placing an order. We appreciate your business and are happy to answer any questions that you may have.